600/1000V 2-Core ~ 4-Core
PVC Insulated, Unarmoured & Armoured, PVC Sheathed Cable
 |
Application : |
The Unarmoured Cable is primarily used as a control cable for main power supply. It is also used for industrial installations such as in cable ducts, on cable trays, on cable ladders, in cable trunking and in switchgears.
The Armoured Cable is primarily used as a control cable for main power supply. It can also be used for industrial installations such as in cable trenches, in cable ducts, in switchgears and in power stations. This cable is ideal for ground emplacement if a higher electrical or mechanical protection is required.
|
Voltage rating : |
600/1000V |
Construction : |
Plain annealed copper, PVC insulated, Unarmoured or Galvanized Steel wires armoured, PVC sheathed cable |
Insulation Colour : |
2-Core: (Red & Black)
3-Core: (Red, Yellow & Blue)
4-Core: (Red, Yellow, Blue & Black) |
Sheath colour : |
Black |
Specification : |
BS6436, IEC60502-1 |
| 2-CORE |
| Cond. Nominal Area |
Thickness of Insulation |
Unarmoured Cable |
Wires Armoured Cable |
| Thickness of Sheath |
Approx. Overall Dia. |
Approx. Cable Weight |
Thickness of Bedding |
Nominal Armour Wire Dia. |
Thickness of Sheath |
Approx. Overall Diameter |
Approx. Cable Weight |
| Extruded |
Lapped |
Extruded |
Lapped |
Extruded |
Lapped |
mm2 |
mm |
mm |
mm |
kg/km |
mm |
mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
1.5 (cs) |
0.8 |
1.8 |
11.2 |
150 |
0.8 |
- |
0.9 |
1.4 |
12.1 |
- |
290 |
- |
2.5 (cs) |
0.8 |
1.8 |
11.6 |
182 |
0.8 |
- |
0.9 |
1.4 |
13.3 |
- |
335 |
- |
4 (cs) |
1.0 |
1.8 |
13.7 |
258 |
0.8 |
- |
0.9 |
1.4 |
15.4 |
- |
465 |
- |
6 (cs) |
1.0 |
1.8 |
15.2 |
290 |
0.8 |
- |
0.9 |
1.5 |
16.8 |
- |
550 |
- |
10 (cs) |
1.0 |
1.8 |
16.1 |
450 |
0.8 |
- |
1.25 |
1.6 |
20.8 |
- |
855 |
- |
16 (cs) |
1.0 |
1.8 |
18.2 |
547 |
0.8 |
- |
1.25 |
1.6 |
22.1 |
- |
1080 |
- |
25 (s) |
1.2 |
1.8 |
19.0 |
680 |
1.0 |
0.8 |
1.6 |
1.7 |
23.0 |
22.6 |
1440 |
1410 |
35 (s) |
1.2 |
1.8 |
21.0 |
940 |
1.0 |
0.8 |
1.6 |
1.8 |
25.0 |
24.5 |
1600 |
1550 |
50 (s) |
1.4 |
1.8 |
23.0 |
1250 |
1.0 |
0.8 |
1.6 |
1.9 |
28.0 |
27.4 |
1990 |
1940 |
70 (s) |
1.4 |
1.9 |
26.0 |
1700 |
1.0 |
0.8 |
1.6 |
1.9 |
30.6 |
30.0 |
2550 |
2455 |
95 (s) |
1.6 |
2.0 |
29.3 |
2326 |
1.2 |
0.8 |
2.0 |
2.1 |
35.8 |
34.7 |
3630 |
3580 |
120 (s) |
1.6 |
2.1 |
31.8 |
2860 |
1.2 |
0.8 |
2.0 |
2.2 |
38.3 |
37.2 |
4220 |
4100 |
150 (s) |
1.8 |
2.2 |
35.1 |
3550 |
1.2 |
0.8 |
2.0 |
2.3 |
41.5 |
40.5 |
5020 |
4860 |
185 (s) |
2.0 |
2.4 |
39.1 |
4361 |
1.4 |
0.8 |
2.5 |
2.4 |
46.4 |
45.2 |
6530 |
6440 |
240 (s) |
2.2 |
2.5 |
43.9 |
5550 |
1.4 |
0.8 |
2.5 |
2.5 |
51.2 |
50.0 |
8185 |
8065 |
300 (s) |
2.4 |
2.7 |
48.7 |
6910 |
1.6 |
0.8 |
2.5 |
2.7 |
56.4 |
54.8 |
9860 |
9685 |
400 (s) |
2.6 |
2.9 |
54.2 |
8600 |
1.6 |
0.8 |
2.5 |
2.9 |
61.9 |
60.3 |
11187 |
11675 |
| 3-CORE |
| Cond. Nominal Area |
Thickness of Insulation |
Unarmoured Cable |
Wires Armoured Cable |
| Thickness of Sheath |
Approx. Overall Dia. |
Approx. Cable Weight |
Thickness of Bedding |
Nominal Armour Wire Dia. |
Thickness of Sheath |
Approx. Overall Diameter |
Approx. Cable Weight |
| Extruded |
Lapped |
Extruded |
Lapped |
Extruded |
Lapped |
mm2 |
mm |
mm |
mm |
kg/km |
mm |
mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
1.5 (cs) |
0.8 |
1.8 |
11.3 |
167 |
0.8 |
- |
0.9 |
1.4 |
12.9 |
- |
305 |
- |
2.5 (cs) |
0.8 |
1.8 |
12.3 |
203 |
0.8 |
- |
0.9 |
1.4 |
14.4 |
- |
390 |
- |
4 (cs) |
1.0 |
1.8 |
14.2 |
302 |
0.8 |
- |
0.9 |
1.4 |
16.0 |
- |
520 |
- |
6 (cs) |
1.0 |
1.8 |
15.8 |
377 |
0.8 |
- |
1.25 |
1.5 |
18.1 |
- |
705 |
- |
10 (cs) |
1.0 |
1.8 |
17.0 |
544 |
0.8 |
- |
1.25 |
1.6 |
21.1 |
- |
945 |
- |
16 (cs) |
1.0 |
1.8 |
19.7 |
759 |
0.8 |
- |
1.25 |
1.6 |
23.5 |
- |
1220 |
- |
25 (s) |
1.2 |
1.8 |
21.0 |
955 |
1.0 |
0.8 |
1.6 |
1.7 |
26.0 |
25.4 |
1700 |
1680 |
35 (s) |
1.2 |
1.8 |
23.0 |
1300 |
1.0 |
0.8 |
1.6 |
1.8 |
27.0 |
26.9 |
2100 |
2070 |
50 (s) |
1.4 |
1.8 |
26.5 |
1720 |
1.0 |
0.8 |
1.6 |
1.9 |
31.0 |
30.6 |
2560 |
2480 |
70 (s) |
1.4 |
1.9 |
29.5 |
2380 |
1.2 |
0.8 |
2.0 |
2.0 |
35.0 |
34.5 |
3360 |
3280 |
95 (s) |
1.6 |
2.1 |
35.0 |
3245 |
1.2 |
0.8 |
2.0 |
2.1 |
39.1 |
38.5 |
4630 |
4550 |
120 (s) |
1.6 |
2.2 |
37.0 |
4030 |
1.2 |
0.8 |
2.0 |
2.2 |
42.1 |
41.4 |
5710 |
5610 |
150 (s) |
1.8 |
2.3 |
41.0 |
5000 |
1.4 |
0.8 |
2.5 |
2.4 |
47.3 |
46.3 |
7160 |
6970 |
185 (s) |
2.0 |
2.5 |
46.0 |
6140 |
1.4 |
0.8 |
2.5 |
2.5 |
51.9 |
50.7 |
8510 |
8330 |
240 (s) |
2.2 |
2.6 |
51.0 |
7960 |
1.6 |
0.8 |
2.5 |
2.6 |
57.8 |
56.2 |
10790 |
10580 |
300 (s) |
2.4 |
2.8 |
58.0 |
9850 |
1.6 |
0.8 |
2.5 |
2.8 |
63.2 |
61.6 |
12940 |
12690 |
400 (s) |
2.6 |
3.1 |
62.2 |
12990 |
1.6 |
0.8 |
3.15 |
3.0 |
69.6 |
68.0 |
16970 |
16715 |
| 4-CORE |
| Cond. Nominal Area |
Thickness of Insulation |
Unarmoured Cable |
Wires Armoured Cable |
| Thickness of Sheath |
Approx. Overall Dia. |
Approx. Cable Weight |
Thickness of Bedding |
Nominal Armour Wire Dia. |
Thickness of Sheath |
Approx. Overall Diameter |
Approx. Cable Weight |
| Extruded |
Lapped |
Extruded |
Lapped |
Extruded |
Lapped |
mm2 |
mm |
mm |
mm |
kg/km |
mm |
mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
1.5 (cs) |
0.8 |
1.8 |
12.3 |
210 |
0.8 |
- |
0.90 |
1.4 |
13.5 |
- |
343 |
- |
2.5 (cs) |
0.8 |
1.8 |
13.2 |
266 |
0.8 |
- |
0.90 |
1.4 |
15.0 |
- |
376 |
- |
4 (cs) |
1.0 |
1.8 |
15.2 |
383 |
0.8 |
- |
1.25 |
1.5 |
17.5 |
- |
686 |
- |
6 (cs) |
1.0 |
1.8 |
16.9 |
440 |
0.8 |
- |
1.25 |
1.5 |
19.5 |
- |
835 |
- |
10 (cs) |
1.0 |
1.8 |
18.6 |
674 |
0.8 |
- |
1.25 |
1.6 |
22.9 |
- |
1125 |
- |
16 (cs) |
1.0 |
1.8 |
21.6 |
924 |
1.0 |
- |
1.60 |
1.7 |
26.5 |
- |
1705 |
- |
25 (s) |
1.2 |
1.8 |
24.0 |
1317 |
1.0 |
0.8 |
1.60 |
1.8 |
28.0 |
27.6 |
2100 |
2050 |
35 (s) |
1.2 |
1.8 |
26.5 |
1735 |
1.0 |
0.8 |
1.60 |
1.9 |
31.0 |
30.8 |
2540 |
2510 |
50 (s) |
1.4 |
1.9 |
30.0 |
2300 |
1.2 |
0.8 |
2.00 |
2.0 |
35.4 |
34.6 |
3500 |
3430 |
70 (s) |
1.4 |
2.0 |
34.0 |
3180 |
1.2 |
0.8 |
2.00 |
2.1 |
39.2 |
38.4 |
4610 |
4540 |
95 (s) |
1.6 |
2.2 |
38.3 |
4367 |
1.2 |
0.8 |
2.00 |
2.2 |
44.4 |
43.5 |
5950 |
5760 |
120 (s) |
1.6 |
2.3 |
41.8 |
5393 |
1.4 |
0.8 |
2.50 |
2.4 |
49.1 |
48.1 |
7610 |
7310 |
150 (s) |
1.8 |
2.5 |
47.5 |
6552 |
1.4 |
0.8 |
2.50 |
2.5 |
53.8 |
52.4 |
9000 |
8700 |
185 (s) |
2.0 |
2.6 |
52.0 |
8183 |
1.6 |
0.8 |
2.50 |
2.6 |
59.2 |
57.4 |
10890 |
10670 |
240 (s) |
2.2 |
2.8 |
58.0 |
10643 |
1.6 |
0.8 |
2.50 |
2.8 |
66.7 |
64.1 |
13630 |
13390 |
300 (s) |
2.4 |
3.1 |
66.0 |
13203 |
1.6 |
0.8 |
3.15 |
3.0 |
72.0 |
70.4 |
16480 |
16240 |
400 (s) |
2.6 |
3.3 |
73.5 |
17090 |
1.8 |
0.8 |
3.15 |
3.3 |
81.3 |
79.3 |
22910 |
22285 |
(cs) : Circular Stranded
(s) : Sector Shaped Stranded Conductors
|