| APPLICATION | This cable is used for general indoor and outdoor purposes. (eg. Portable tools, washing machines and vacuum cleaners) |
| VOLTAGE RATING |
250/440V |
| CONSTRUCTION | Flexible plain annealed copper conductor, PVC insulated, PVC sheathed cable |
| INSULATION COLOUR |
|
| SHEATH COLOUR |
Grey, White or as per order |
| SPECIFICATION | BS2004 |
Detailed SpecificationNo. of Core |
Conductor |
Insulation |
Sheath |
Overall Diameter |
Approx. Cable Weight |
|
Nominal Area |
No./Dia of Strand |
Thickness |
Thickness |
|||
mm2 |
No./mm |
mm |
mm |
mm |
kg/km |
|
Single Core |
0.4 |
14/0.193 |
0.64 |
- |
2.47 |
11 |
2-core |
1.02 |
6.55 |
56 |
|||
3-core |
1.02 |
6.88 |
67 |
|||
4-core |
1.02 |
7.44 |
79 |
|||
Single Core |
0.7 |
23/0.193 |
0.64 |
- |
2.63 |
13 |
2-core |
1.02 |
7.16 |
70 |
|||
3-core |
1.02 |
7.54 |
87 |
|||
4-core |
1.02 |
8.18 |
100 |
|||
Single Core |
1.2 |
40/0.193 |
0.64 |
- |
2.80 |
17 |
2-core |
1.02 |
7.72 |
88 |
|||
3-core |
1.02 |
8.15 |
107 |
|||
4-core |
1.02 |
9.37 |
141 |
|||
Single Core |
2.0 |
70/0.193 |
0.64 |
- |
3.25 |
27 |
2-core |
1.27 |
9.19 |
129 |
|||
3-core |
1.27 |
9.70 |
158 |
|||
4-core |
1.27 |
10.54 |
192 |
|||
Single Core |
3.2 |
110/0.193 |
0.64 |
- |
3.75 |
40 |
2-core |
1.27 |
10.01 |
167 |
|||
3-core |
1.27 |
10.57 |
208 |
|||
4-core |
1.27 |
11.51 |
258 |
|||
Single Core |
4.7 |
162/0.193 |
0.76 |
- |
4.95 |
58 |
2-core |
1.27 |
11.53+ |
227 |
|||
11.94* |
228 |
|||||
3-core |
1.27 |
12.22+ |
286 |
|||
12.67* |
288 |
|||||
4-core |
1.27 |
13.46+ |
350 |
|||
13.97* |
353 |
|||||
Current Rating and Voltage DropFlexible Cables with PVC Insulation, or PVC Insulation & PVC Outsheath
Technical Data Flexible Cord, Imperial Sizes (CU/PVC or CU/PVC/PVC)
| Conductor Operating Temperature : 90°C | BS 2004 |
| Ambient Temperature : 30°C |
Conductor |
Current Rating |
Voltage Drop per 100 feet |
Maximum Weight |
||
Nominal Area |
Construction |
1 or 3 phase a.c. or d.c. |
d.c. or 1 phase a.c. |
3 phase a.c. |
|
in2 |
No. / in |
Amp |
V |
V |
lb |
0.0006 |
14 / 0.0076 |
3 |
8.9 |
7.7 |
3 |
0.0010 |
23 / 0.0076 |
6 |
11 |
9.4 |
5 |
0.0017 |
40 / 0.0076 |
13 |
14 |
12 |
10 |
0.0030 |
70 / 0.0076 |
18 |
12 |
10 |
10 |
0.0048 |
110 / 0.0076 |
24 |
9.6 |
8.3 |
10 |
0.0070 |
162 / 0.0076 |
31 |
8.4 |
7.3 |
10 |
Technical Data Flexible Cord, Imperial Sizes (CU/PVC or CU/PVC/PVC)
| Conductor Operating Temperature : 90°C | BS 6500 |
| Ambient Temperature : 30°C |
Conductor |
Current Rating |
Voltage Drop per 100 feet |
Maximum Weight |
||
Nominal Area |
Construction |
1 or 3 phase a.c. or d.c. |
d.c. or 1 phase a.c. |
3 phase a.c. |
|
mm2 |
No. / mm |
Amp |
mV/m |
mV/m |
Kg |
0.50 |
16/0.2 |
3 |
83 |
72 |
2 |
0.75 |
24/0.2 |
6 |
56 |
48 |
3 |
1.00 |
32/0.2 |
10 |
43 |
37 |
5 |
1.25 |
40/0.2 |
13 |
35 |
29 |
5 |
1.50 |
30/0.25 |
16 |
31 |
26 |
5 |
2.50 |
50/0.25 |
25 |
18 |
16 |
5 |
4.00 |
56/0.30 |
32 |
11 |
10 |
5 |
![]()

+ Bunched Conductor
* Rope-Stranded Conduct
(1mm=0.039 inch)